{"id":3341,"date":"2018-02-20T14:42:33","date_gmt":"2018-02-20T13:42:33","guid":{"rendered":"https:\/\/laser.usal.es\/alf\/?p=3341"},"modified":"2021-11-25T15:12:05","modified_gmt":"2021-11-25T14:12:05","slug":"midiendo-pulsos-con-una-regla-sin-calibrar","status":"publish","type":"post","link":"https:\/\/laser.usal.es\/alf\/es\/2018\/02\/20\/midiendo-pulsos-con-una-regla-sin-calibrar\/","title":{"rendered":"Midiendo pulsos con una regla sin calibrar"},"content":{"rendered":"<section class=\"section  text-normal section-text-no-shadow section-inner-no-shadow section-normal section-opaque\"  >\n    \n    <div class=\"background-overlay grid-overlay-0 \" style=\"background-color: rgba(0,0,0,0);\"><\/div>\n\n    <div class=\"container container-vertical-default\">\n        <div class=\"row vertical-default\">\n            <div class=\"col-md-12     text-default small-screen-default\"  ><div class=\"col-text-1 text-normal  element-top-20 element-bottom-20\" data-os-animation=\"none\" data-os-animation-delay=\"0s\">\n    <p>Los pulsos l\u00e1ser ultracortos son unos de los eventos artificiales m\u00e1s breves. Su duraci\u00f3n t\u00edpica est\u00e1 en la escala del femtosegundo (1\/1000000000000 s), aunque hay t\u00e9cnicas que permiten ir m\u00e1s lejos. Encontrar un patr\u00f3n con el cual medirlos es misi\u00f3n imposible, as\u00ed que la soluci\u00f3n m\u00e1s ingeniosa y eficaz que se ha encontrado es utilizar el propio pulso para medirse a s\u00ed mismo.<\/p>\n<p>La luz pulsada ultracorta, compuesta a veces de un amplio abanico de colores, se emite con formas muy diversas. Mediante la detecci\u00f3n de procesos no lineales, se puede ver una huella de esas formas y medir los pulsos. En nuestro caso, utilizamos un proceso conocido como generaci\u00f3n de segundo arm\u00f3nico, en el cual los fotones (part\u00edculas de luz) del pulso se unen de dos en dos para duplicar su energ\u00eda.<\/p>\n<p>Adem\u00e1s, para obtener la huella adecuada (un mapa que esconde la forma del pulso), es necesario detectar este proceso mientras modificamos el pulso a medir, por ejemplo, haciendo que los distintos colores del pulso viajen \u201ccaminos \u00f3pticos\u201d diferentes, lo que se conoce como dispersi\u00f3n, y hace que el pulso sea m\u00e1s largo. La t\u00e9cnica descrita, conocida como barrido de dispersi\u00f3n (<em>d-scan<\/em>, en ingl\u00e9s), fue desarrollada por investigadores de la Universidad de Oporto (Portugal) y la Universidad de Lund (Suecia).<\/p>\n<p>El presente trabajo propone un algoritmo avanzado que es capaz de medir el pulso y a la vez obtener los \u201ccaminos \u00f3pticos\u201d (dispersi\u00f3n) que han sido utilizados para obtener esa huella o traza. Por eso decimos que la regla utilizada, que mide esos caminos, no estaba calibrada antes de medir. Gracias a ello, ser\u00e1 posible medir f\u00e1cilmente los pulsos incluso en montajes poco accesibles en el laboratorio, o cuando se utilicen pulsos con un amplio rango de duraciones.<\/p>\n<p>Puedes descubrir todos los detalles de este trabajo, colaboraci\u00f3n entre la Universidad de Salamanca y la de Oporto, en el siguiente enlace:<\/p>\n<p>Alonso, I. J. Sola &amp; H. Crespo, <a href=\"http:\/\/rdcu.be\/Hkun\">Self-calibrating d-scan: measuring ultrashort laser pulses on-target using an arbitrary pulse compressor<\/a>,\u00a0Scientific Reports <strong>8<\/strong>, Article number: 3264 (2018)<\/p>\n<\/div>\n<\/div>        <\/div>\n    <\/div>\n<\/section>\n\n\n<div class=\"twitter-share\"><a href=\"https:\/\/twitter.com\/intent\/tweet?text=Nueva%20rese%C3%B1a%20divulgativa%20a%20la%20%C3%BAltima%20publicaci%C3%B3n%20del%20grupo%3A%20Midiendo%20pulsos%20con%20una%20regla%20sin%20calibrar.%20%C2%A1A%20disfrutar%21&#038;via=OpticaExtrema\" class=\"twitter-share-button\">Twittear<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"Los pulsos l\u00e1ser ultracortos son unos de los eventos artificiales m\u00e1s breves. Su duraci\u00f3n t\u00edpica est\u00e1 en la escala del femtosegundo (1\/1000000000000 s), aunque hay t\u00e9cnicas que permiten ir m\u00e1s lejos. Encontrar un patr\u00f3n con el cual medirlos es misi\u00f3n imposible, as\u00ed que la soluci\u00f3n m\u00e1s ingeniosa y eficaz que se ha encontrado es utilizar","protected":false},"author":1,"featured_media":3342,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[388],"tags":[],"class_list":["post-3341","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-resena"],"_links":{"self":[{"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/posts\/3341","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/comments?post=3341"}],"version-history":[{"count":1,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/posts\/3341\/revisions"}],"predecessor-version":[{"id":3343,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/posts\/3341\/revisions\/3343"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/media\/3342"}],"wp:attachment":[{"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/media?parent=3341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/categories?post=3341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/laser.usal.es\/alf\/wp-json\/wp\/v2\/tags?post=3341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}